Evolver NE Solventborne Robotic Atomizers - Maintenance

>

The fluid tip [34] should always be installed

and tightened before installing the needle

and valve springs.

NOTE

>

After tightening the fluid tip, always check

to see if the proper gap of 1/16" (1.59mm)

between the needle nuts and air valve stem

occur, before installing the needle and valve

springs back into the head.

!

C A U T I O N

NOTES

10. Screw fluid tip [34] back into place. Hand tighten

first, then with a small wrench, tighten an additional

30

°.

11. Replace air cap locator [33], air cap [35], and air

cap retainer [36].

12. Apply a thin film of petroleum jelly to valve and

needle springs [2] and [3]. Install the springs back

into the end cap and the spray head assembly.

13. Screw end cap [1] back on.

The spray head can be removed from assembly as

shown in Figure 5 for cleaning and service.

AA-05-01.5