Recover/Recycle/Recharge Unit

9

7. With the vacuum pump running, slowly add oil until the level rises to

the center of the oil sight glass.

NOTE: The pump holds approximately 237 mL (8 ounces) of oil.

8. When the vacuum pump countdown reaches zero, the vacuum pump

stops, and the unit display changes to the recover function.

9. Replace the plastic plug in the oil fill port.

After adding oil to the vacuum pump, add refrigerant to the internal
storage vessel. Refer to the instructions on the next page.

Note: The unit’s
weight default is in
kilograms. To change
the default to pounds:
1. Press the Up and

Down arrow keys
at the same time.

will be displayed.

2. Press the Up or

Down arrow key to
toggle to LBS.

3. Press the Menu

(

)

key until the

display reads EXIT.

4. Press Start/Stop

( )

key to exit.

UNITS KG