Operation

Before recharging the A/C system, replenish the A/C system oil. Add only the
amount of oil that was removed during recovery. If no oil was removed, do
not add any oil.

NOTE:

• Consult the A/C system manufacturer for correct oil replacement proce-

dures and oil specifications.

Replacing A/C system components may require adding more oil. Consult

the component manufacturer for recommendations.

1. Refer to amount of oil that was removed during recovery. (See Step 4 on

page 18.)

2. Fill oil injector bottle with new oil:

Add 30–60 mL (1–2 ounces) more oil than was recovered in Step 4 on
page 18.

Add any additional oil required by A/C component change.

3. Note the level of new oil in the bottle.

4. Turn the high-side valve to the Oil Inject position (

) until the system is

replenished with the desired amount of oil. NOTE: To avoid getting air
into the A/C system, do not remove all the oil from the oil inject bottle.

5. Close the high-side valve.

6. Press the Start/Stop key ( ) to exit the vacuum function.

To ensure replenishment of oil into the A/C system, immediately recharge the
A/C system. Refer to instructions on the next page.

Replenishing the A/C System Oil