5. On the control panel, open the low-side valve; verify the high-side valve is

closed.

6. Press the Start/Stop key ( ). The internal storage vessel begins filling,

and the screen displays the amount of refrigerant being transferred to the
internal storage vessel.

7. The unit automatically stops when 7 kg (15 lbs.) has been transferred to

the internal storage vessel. The display will flash between:

and

NOTE: Do not drain oil until the following steps are complete. Drain oil
instructions begin on next page.

8. Unstrap the source tank, remove it from its compartment, and close the

source tank valve.

9. Disconnect the hose from the tank.

10. Cap the source tank with its original tank cap. For storage, place the source

tank upright in the source tank compartment. Secure the source tank in
place by wrapping the strap around the tank and then fastening the strap.

11. Press the Start/Stop key ( ) to exit the recover function.

RECOVER XX.XXKG

Adding Refrigerant to the Internal Storage Vessel contd.

Initial Setup

DRAIN OIL

Control Panel

Start/Stop Key

Oil Drain Valve

Display Screen

Menu Key

Up Arrow

Down Arrow

ISV Pressure

Gauge

Low-Side

Gauge

High-Side

Gauge

Low-Side

Panel Valve

High-Side

Panel Valve /

Oil Inject

Power Switch