Getting started – SKC Limited Pocket Pump MTX User Manual

Page 15

Advertising
background image

www.skcltd.com

210-PMTXM Issue F

Page 13

Getting Started

power SLEEP mode, with the LCD screen switched off. To wake the pump from SLEEP mode simply press
any of the three buttons and the pump LCD screen will display the pump serial number followed by the internal
software version number before switching to HOLD mode.
The pump will also automatically wake from SLEEP mode when the battery charger is connected.

6) HOLD and RUN Modes

To switch from HOLD mode to RUN mode press [ ]. The pump will start to run and the run-time data will
be updated continuously in memory.
To switch from RUN mode to HOLD mode press [ ]. The pump will stop and retain the run-time data in
memory. The temperature and back pressure readings are still active in HOLD mode, and can be displayed on
the LCD screen (in Enhanced Display mode).

7) Flow Fault

If pump operation is interrupted due to blocked or restricted flow, the flow fault indicator

will flash. If the

flow fault persists for 15 seconds the pump will stop and switch to HOLD mode, with the flow fault indicator
on continuously. The pump will then wait 5 minutes before automatically switching to RUN mode to continue
sampling. If the flow remains restricted the pump will return to HOLD mode, and attempt to restart every 5
minutes.
The accumated run time and and sample volume readings are not updated whilst the pump is in flow fault.

8) Resetting the Run-Time Data to Zero

To clear the run-time data including elapsed run time and accumulated sample volume, the following sequence
is required:
With the pump running, press [ ] to switch to HOLD mode, press , and then .

Advertising