Harrington Hoists and Cranes MR Trolley - (MR2) User Manual

Page 30

Advertising
background image

3.5.9 The Run Lamp display provides trolley “RUN” status. Table 3-6 shows the various “RUN” displays.

Table 3-6 Run Lamp

3.5.10 All of the dual speed trolleys have speed/frequency ranges that can be customized to a specific

application. Refer to Table 3-7 for specific trolley speed/frequency ranges. To set custom speeds for
an application, follow the procedure in Table 3-8.

Table 3-7 VFD Speed & Frequency Ranges

Product

Code

Trolley Speed (ft/min)

VFD Frequency (Hz)

Range*

Low

High

Low (d1-01)

High (d1-02)

230V

460V

230V

460V

MR2010SD

Low

8.0

80.0

6.7

6.7

63.0

63.0

Std

13.0

80.0

11.0

11.0

63.0

63.0

MR2020SD

Low

8.0

80.0

6.7

6.7

63.0

63.0

Std

13.0

80.0

11.0

11.0

63.0

63.0

MR2030SD

Low

8.0

80.0

6.7

6.7

63.0

63.0

Std

13.0

80.0

11.0

11.0

63.0

63.0

MR2050SD

Low

8.0

80.0

6.7

6.7

63.0

63.0

Std

13.0

80.0

11.0

11.0

63.0

63.0

*Low = The minimum and maximum speed/frequency range (10:1 ratio).
Std = The factory standard minimum and maximum speed/frequency range (6:1 ratio).

30