Harrington Hoists and Cranes MR Trolley - (MR2) User Manual

Page 32

Advertising
background image


Table 3-10 Trolley VFD 2-Step/3-Step Infinitely Variable Parameter Setup Procedure



 Each dual speed trolley model has a range of available speeds/frequencies (upper and lower limits) and

acceleration/deceleration time parameters. Refer to Owner’s Manual MOTORIZED TROLLEY MR2
SERIES.

 Any value outside the range listed in Table 3-7 for your specific trolley is strictly prohibited.
 Speeds must be set such as Low [d1-01] and High [d1-02].
 After parameters are changed, a “no load” operational check must be performed.

Operational Step

VFD Display

Change Mode to 2 Step or 3 Step.

1. Press

or

until the “Setup Mode” screen is displayed (blinking).

2. Press

to display “d1-01”.

3. Tables 3-7 and 3-9 lists the values that may be changed.

Title

Parameter

Description

Min. Frequency (Hz) – Low Speed

d1-01

11 Hz (default setting)

Max. frequency (Hz) – High Speed

d1-02

63 Hz (default setting)

Mode

S1-25

1. Standard 2 Speed (default)

2. 2-Step Infinitely Variable

3. 3-Step Infinitely Variable

Acceleration Time (sec.)

(0 to 120 Hz) in 2 or 3 Step Mode.

S1-26

Apply for frequency range between d1-01 and
d1-02.

Deceleration Time (sec.)

(0 to 120 Hz) in 2 or 3 Step Mode.

S1-27

Apply for frequency range between d1-01 and
d1-02.

Acceleration Time (sec.) (0 to 120 Hz) in 2 speed.

C1-01

In 2 or 3 Step Mode, apply for the frequency
range between starting frequency (6.6 Hz) and
d1-01.

Deceleration Time (sec.) (0 to 120 Hz) in 2 speed.

C1-02

Acceleration Time (sec.) (0 to 120 Hz) in 2 speed.

C1-03

Deceleration Time (sec.) (0 to 120 Hz) in 2 speed.

C1-04

4. Press

several times.

3.5.12 “Hbb” will appear on the dual speed unit’s VFD display when the Emergency Stop Button is depressed.

Turn the Emergency Stop Button clockwise to unlock the controls and allow hoist operation.

32