Harrington Hoists and Cranes MR Trolley - (MR2) User Manual

Page 48

Advertising
background image




Table 7-1 Troubleshooting Guide

Symptom

Cause

Remedy

Trolley drifts
excessively when
stopping

Motor brake not
holding

Clean and inspect brake lining. Replace if necessary

VFD Deceleration
parameter adjusted
incorrectly
(Dual Speed only)

Readjust VFD Deceleration parameter (Reference Section
3.5.11).

Motor or brake
overheating

Excessive duty cycle

Reduce frequency of trolley movement.

Extreme external
heating

Above an ambient temperature of 140°F, the frequency of trolley
operation must be reduced to avoid overheating of the motor.
Special provisions should be made to ventilate the trolley or
otherwise shield it from the heat.

Trolley operates
intermittently

Collectors making poor
contact

Check movement of spring loaded arm, weak spring, connections,
and shoe. Replace as needed.

Contactor contacts
arcing

Check for burned contacts. Replace as needed.

Faulty VFD
(dual speed only)

Check fault codes (Reference Section 3.5). Replace as needed.

Loose connection in
circuit

Check all wires and terminals for bad connections. Replace as
needed.

Broken conductor in
Pendant Cord

Check for intermittent continuity in each conductor the Pendant
Cord. Replace entire Pendant Cord if continuity is not constant.

























48

Advertising