Table 3-8 Dual Speed Trolley (w/VFD) Speed/Frequency Change Procedure



 Each dual speed trolley has a range of available speeds/frequencies (upper and lower limits). Any value

outside the range listed in Table 3-7 for your specific trolley is strictly prohibited.

 Speeds must be set such as Low [d1-01] and High [d1-02].

 After parameters are changed, a “no load” operational check must be performed.

Operational Step

VFD Display

1. Energize the trolley.

2. Press

until the “Setup Mode” screen is displayed (blinking).

3. Press

to display the parameter setting screen (blinking).

4. Press

or

until the desired parameter is displayed (blinking).

(Low Speed: d1-01, High Speed: d1-02)

5. When you press

, the current setting value is displayed (digit selected blinks).

(Example Value: 9Hz)

6. Press

to move the blinking digit to the desired digit. (Example Value: 9 blinks)

7. Press

or

until the desired setting is displayed and press

.

(Example Value: 8Hz)

8. Press

to confirm the new setting.

9. The display will automatically return to the parameter screen (blinking). (As in Step 4.)

10. Press

until the diplay returns to the initial screen. (As in Step 1.)

3.5.11 All dual speed trolleys have a acceleration/deceleration time parameter range that can be customized

to a specific application. Refer to Table 3-9 for specific trolley acceleration/deceleration time ranges.
To set custom acceleration/deceleration times for an application, follow the procedure in Table 3-10.

Table 3-9 VFD Acceleration/Deceleration Time Parameter Ranges

Item

Parameter No.

Initial

Value

Unit

Setting

Range

Remark

Acceleration Time

C1-01

4.0

Seconds

1.2 – 6.0

Set the same value to the two
parameters

C1-03

Deceleration Time

C1-02

4.0

Seconds

1.2 – 6.0

Set the same value to the two
parameters

C1-04