z AXST (Get axis status)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional

AXST

Variable

number

Axis

number

CP

[Function] Store in the variable specified in operand 1 the status (axis error number) of the axis

specified in operand 2.

1RWH 

,IWKHREWDLQHGUHVXOWLV³´ it means no axis error is present.

(Note 2)

Since the error lists are written in hexadecimals, they must be converted to decimals.

[Example]

AXST

1

2

Read the error number for axis 2 to variable 1.

If 3188 (decimal) is stored in variable 1 after the execution of this command:

3188

y 16 = 199 ,,,4

199

y 16 = 12 (= C) ,,,7

3188 = 12 (= C) X 16

2

+ 7 X 16 + 4

= C74 (HEX) (Hexadecimal number)

7KHUHIRUHDQ³(UURU1R&$FWXDOSRVLWLRQVRIWOLPLWRYHUHUURU´LVSUHVHQW