18 communication – IAI America XSEL-KE User Manual

Page 209

Advertising
background image

194

Part 4 Commands

1.18 Communication

z OPEN (Open channel)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional

OPEN

Channel

number

Prohibited CP

[Function] Open the channel specified in operand 1.

The specified channel will be enabled to send/receive hereafter.
Prior to executing this command, a SCHA command must be used to set an end character.

[Example] SCHA

10

OPEN 1

Specify 10 (= LF) as the end character.
Open channel 1.

1RWH ,I³23(1´LVH[HFXWHGWKHteaching-pendant connector (D-sub,

25-pin) will be disconnected. (This is because channel 1 is shared
by the teaching pendant/PC software.)

z CLOS (Close channel)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional

CLOS

Channel

number

Prohibited CP

[Function] Close the channel specified in operand 1.

The specified channel will be disabled to send/receive hereafter.

[Example] CLOS

1

Close channel 1.

LET 1

2

CLOS *1

Assign 2 to variable 1.

Close the content of variable 1 (channel 2).