[4] Position Setting Operation Example

The operation procedure is described taking a specific example.

1)

Position, Velocity or Acceleration/Deceleration Setting
Explained below is the case for 2-point stop as an example.
The position setting is performed for the reciprocating movement between 10.0 mm and
100.0 mm.

Forward Position (Backward Point) :100.0mm, Backward Position (Forward Point) :10.0mm,
Reciprocating Movement Speed: 50mm/sec, Reciprocating Movement Acceleration: 0.3G,
Reciprocating Movement Deceleration: 0.3G

No. Operation

Window

Remarks

1

Touch Pos. Edit in the MEC
MENU window.


2

In the case of the password
value except for “0000”, the
password input window is
displayed.
Input the password.

The password for positioning
command can be set in
‘parameter No. 20 Password
for Position Data Edit’ under
Parameter Edit.

3

Set the backward position
(stop position on the forward
point), the positions related
to it and acceleration/
deceleration speed.


Touch the BackwardPos.

When

MENU is touched, the

MEC MENU window is
returned.

4

Touch the value for the
position.

Touching Tb1 return to the
Forward Position/Backward
Position setting window in
the Position Setting window.

5

Touch 1, 0, then

.

When the value input is
stopped, touch ESC. The
value will not be set and the
previous position setting
window will be returned.

6

“10.00” is displayed in the
position data section.

Touching Tb1 return to the
Forward Position/Backward
Position setting window in
the Position Setting window.