IAI America SEP-PT User Manual

Page 43

Advertising
background image

37

[4] Position Setting Operation Example

The operation procedure is described taking a specific example.

1)

Position, Velocity or Acceleration/Deceleration Setting
It is described taking Operation Mode 0 (Standard) as an example.
The position setting is performed for the reciprocating movement between 10.0 mm and
100.0 mm.

Forward Position:100.0mm, Backward Position:10.0mm,
Reciprocating Movement Speed: 50mm/sec, Reciprocating Movement Acceleration:
0.3G, Reciprocating Movement Deceleration: 0.3G

No. Operation

Window

Remarks

1

Touch Pos Edit in the
SEP-PT MENU window.


2

In the case of the password
value except for “0000”, the
password input window is
displayed.
Input the password.

The password for positioning
command can be set in
‘parameter No. 20 Password
for Position Data Edit’ under
Parameter Edit.

3

Set the Backward Position
related position, acceleration
and deceleration.
Touch the BackwardPos.

When

MENU is touched, the

SEP-PT MENU window is
returned.

4

Touch the value for the
position.

Touching Tb1 return to the
Forward Position/Backward
Position setting window in
the Position Setting window.

5

Touch 1 and 0 and

then

.

When the value input is
stopped, touch ESC. The
value will not be set and the
previous position setting
window will be returned.

6

“10.00” is displayed in the
position data section.

Touching Tb1 return to the
Forward Position/Backward
Position setting window in
the Position Setting window.