IAI America SEP-PT User Manual

Page 52

Advertising
background image

46

3) Jog Operation (The actuator is moved (inching movement) using the direction arrow button ĸ

or ĺ to align with the target position and the position (current position) is captured as forward
position or backward position).
It is described taking Operation Mode “0” (Standard Point-to-Point Movement) as an example.
The procedure for capturing the current position of “80.0mm” in the Backward Position).

No. Operation

Window

Remarks

1


Touch Pos Edit in the
SEP-PT MENU window.




2


In the case of the password
value except for “0000”, the
password input window is
displayed.

Input the password.

The password for positioning
command can be set in
‘parameter No. 20 Password
for Position Data Edit’ under
Parameter Edit.

3


Set the Backward Position
related position, acceleration
and deceleration.

Touch the BackwardPos.

When MENU is touched, the
SEP-PT MENU window is
returned.


4


Touch the JOG

.

Touching Tb1 return to the
Forward Position/Backward
Position setting window in
the Position Setting window.

5

When the home return
operation has not been
completed, the window for
performing the home return
operation is displayed.
When the home return
operation has been
completed, go to operation
step No. 8.

Touch YES to perform the
home return operation.

6

Touch the OK.

Advertising