When the section of the position to be set is touched, the target position/velocity setting window
for the selected position is displayed.
Set the position and velocity.
Touching Tb1 returns to the Tb1 window.
In this set window, the other three setting item and job movement can be selected.
[Setting Items]
x PUSH
Pressing Force and Pressing Width Setting
x Acceleration/Deceleration
Acceleration and Deceleration Setting
x ECO
Energy-Saving Function Setting
[1] Position
Data
The position data for operating the actuator is set here.
Position Data
Position Setting
Window
Position/Velocity Acceleration/Deceleration
Pressing
Energy-Saving
1)
2)
3)
4)
5)
6)
7)
Position Data
Position
[mm]
Velocity
[mm/s]
Acceleration
[G]
Deceleration
[G]
Pressing
Force
[%]
Pressing
Width
[mm]
Energy-Saving
Function
Forward
Position
200.00 50.00
0.1
0.1
70
1.00
Effective
Backward
Position
0.00 50.00 0.1
0.1
0
0
Effective
Intermediate
Point Position
100.00 50.00
0.1
0.1
0
0
Effective
1) Position… Set the position where the actuator is moved.
The correlation of the Positions is as shown below:
Backward Position < Intermediate Point Position < Forward Position
Set Position
Operation Pattern
Displacement
Forward
Position
Backward
Position
Intermediate
Point Position
Standard Point-to-Point
Movement :0
2-Point Movement
ż ż
Movement Speed Setting :1
2-Point Movement
ż ż
Position Data Change:2
2-Point Movement
ż ż
2-Input, 3-Point Movement :3
3-Point Movement
ż ż ż
3-Input, 3-Point Movement :4
3-Point Movement
ż ż ż
Continuous Reciprocating
Operation :5
2-Point Movement
ż ż
2) Velocity…Set the actuator speed.
3) Acceleration…Set the actuator acceleration.
It is available to input greater number than specified in the Catalog for the
range of input.
Refer to the Catalog or the Instruction Manual of the actuator.
The set position is shown.
The set
velocity is shown.
Backward Position
Intermediate
Point Position
Forward Position
Motor
Actuator