Functional descriptions, 1-3 auxiliary output switching function – IDEC SE4D Type 4 Hand User Manual

Page 11

Advertising
background image

10

Functional Descriptions

<Minimum sensing object>

Floating blanking function

Ineffective

Effective

1 beam channel

2 beam channels

3 beam channels

SE4D-H

ø25mm

ø45mm

ø65mm

ø85mm

3-1-3 Auxiliary Output Switching Function

This function changes the operation state of the auxiliary output. It is useful when desired to make an

indicator to operate or inform the operation state of the

SE4D series to PLC.

The following settings are selectable.

Setting

mode

Auxiliary output setting

Operation of the auxiliary output corresponding to

SE4D series state

Emission

halt

State of sensing area when emitting

Lockout

Unshielded

Shielded

Unstable

light-receiving

condition

Others

0

Negative logic of the control

output (OSSD 1 / 2)

(factory setting)

ON

OFF when OSSD is ON

ON when OSSD is OFF

ON

1

Positive logic of the control

output (OSSD 1 / 2)

OFF

ON when OSSD is ON

OFF when OSSD is OFF

OFF

2

ON when emitting

OFF

ON

OFF

3

OFF when emitting

ON

OFF

ON

4

OFF under unstable light

receiving condition (Note 1)

(Note 3)

OFF

ON

(Note 3)

(Note 3)

5

ON under unstable light

receiving condition (Note 1)

(Note 3)

ON

OFF

(Note 3)

(Note 3)

6

ON during muting

OFF

ON during muting

Others: OFF

OFF

7

OFF during muting

ON

OFF during muting

Others: ON

ON

8

ON in light receiving condition

(Note 2)

OFF

ON

OFF

OFF

9

OFF in light receiving condition

(Note 2)

ON

OFF

ON

ON

Notes: 1) When the fixed blanking function, the floating blanking function or the muting function is used, the setting of ON / OFF

under unstable light-receiving condition does not work.

2) By the setting of ON / OFF in light receiving condition, light-receiving / light interrupted condition is output regardless of

the fixed blanking function, the floating blanking function or the muting function.

<e.g.>

When the fixed blanking function is used, if an obstacle exists in the set area and other area is in light receiving

condition, the control output (OSSD 1 / 2) is in ON sate, however, the auxiliary output becomes OFF since the

SE4D

series has been detecting the obstacle.

3) The state of the auxiliary output remains the same even if the

SE4D series state changes.

If the floating blanking function is used, the incident light intensity indicator is turned OFF

when an obstacle exists in the sensing range regardless of the incident light intensity.

Do not use the auxiliary output for the purpose of stopping the machine in which the

SE4D

series is installed. Failure to do so could result in death or serious injury.