Function Setting

3-2-3 Auxiliary Output Switching Function

*: When two or more

SE4D series are connected, cancel the protective function of all SE4D series.

<Setting of the auxiliary output>

Mode 0: Negative logic of the control output (OSSD 1 / 2) (factory setting)

Mode 1: Positive logic of the control output (OSSD 1 / 2)

Mode 2: ON during emission, OFF when emission is not done.

Mode 3: OFF during emission, ON when emission is not done.

Mode 4: OFF when the received light level is unstable (Note 1)

Mode 5: ON when the received light level is unstable (Note 1)

Mode 6: ON during muting

Mode 7: OFF during muting

Mode 8: ON in the light receiving condition

Mode 9: OFF in the light receiving condition

Notes: 1) This cannot be used when the fixed blanking function, the floating blanking function or the muting setting changing

function is used.

2) When using with

SE4D series only, if the external device monitor function is not used, set the monitor setting to

ineffective in “

3-2-8 External Device Monitor Setting Changing Function.”

(Mode 9)