CHAPTER 4 TROUBLESHOOTING

Symptoms

Cause

Remedy

Control output (OSSD

1 / 2) is not turned ON.

This device is connected to the

SE4D

series.

Disconnect this device.

Error indication

Cause

Remedy

The fixed blanking function is set in all

lights received / all lights blocked

condition, or the muting function is set in

all lights received condition.

Do not set the fixed blanking function in all

lights received / all lights blocked condition,

or the muting function in all lights received

condition.

The copy function is used for the units

having different system configuration from

each other (the number of sensors / the

number of beam channels / model No. is

not same).

Use the copy function for the units having

identical system configuration.

In the copy function, download the data

without uploading.

Upload the data before downloading.

The password does not match.

Input the correct password. In case you

forget the password, contact us. (Note)

Sensor communication error 1

(Model No. is wrong)

Connect this device to

SE4D series.

Sensor communication error 2

Wrong wiring between the emitter and

receiver.

Connect the emitter and receiver correctly.

Sensor communication error 3

Effect from noise or failure of internal

circuit

Check the noise state around the

SE4D

series.

Failure of EEPROM in this device.

(Failure on device)

Contact us.

Failure of EEPROM in this device.

(Failure on EEPROM data)

Contact us.

Note: The factory setting of the

SE4D series password is “0000.”

If this device does not work, press ENTER key or CANCEL key one minute after pressing ENTER

key.

If the device does not work correctly after checking the items above, please consult us.