8

CHAPTER 3 FUNCTIONS

If configuration of the system is changed (replace the

SE4D series etc.), set the function

again.

3-1-1 Fixed Blanking Function

This is a function that the control output (OSSD 1 / 2) of

SE4D series is not turned OFF, even if the

specified beam channel(s) is blocked OFF.

This is useful when an obstacle always blocks OFF the specific beam channel(s).
There are “Clear,” “Auto” and “Manual” for the setting method.

● Clear setting : The fixed blanking function is to be invalid (factory setting).

● Auto setting : The currently blocked OFF beam channels are set as “effective beam channels”

in the fixed blanking function. Be sure to set this function in the state where the

emitter emits light. Furthermore, this function cannot be set in the state where all

beam channels receive lights / are blocked.

● Manual setting : Each beam channel can be set to “effective / ineffective” in the fixed blanking

function respectively.

3-1 Functional Descriptions

When the fixed blanking function is used, the control output (OSSD 1 / 2) of

SE4D series

is not turned OFF even if the particular beam channels are blocked.

By using a protection structure etc., make the dangerous parts of the machine inaccessible

to personnel through the sensing area of the particular beam channels.

<Before measures>

<After measures>

Obstacle

Dangerous area

Protection structure

Beam channels the fixed blanking

function has been set to ON

Beam channels the fixed blanking

function has been set to ON

Emitter

Receiver

Emitter

Receiver

When the effective beam channel(s) in the fixed blanking function receive(s) the beam(s)

from the emitter, the control output (OSSD 1 / 2) of the

SE4D series is fixed to “OFF.” In

this case, check the mounting condition and turn the power ON again.

(Even if the power is turned ON again, the fixed blanking function still stays effective.)

When the fixed blanking function is used, the received light intensity indicator of

SE4D

series is turned OFF regardless of the received light intensity.