For a setup where C

t

= 0.7 pF and a source resistance is 250 Ω, the measured rise time will be 0.385

ns, which will correspond to a bandwidth of 909 MHz, assuming no inductive loads.

(

t

rise

=2.2 x 0.7 X 10

-12

x 250 Ω = 0.385 ns

)

(

parallel combination of 250 Ω and 100 kΩ is still 250 Ω

)

Figure 3

Probe input equivalent circuit

To illustrate the effect of capacitive loading at higher frequencies:

At a frequency of 851 MHz the reactance of the 0.7 pF capacitance is 267 Ω, and at 1.0 GHz the
reactance has been lowered to 227 Ω

If, at a given frequency, the source impedance is large with respect to the input impedance, a
measurable reduction in the output signal amplitude may occur.

where: Z

probe

is the probe’s input impedance and Z

source

is the source impedance

As an example:

At 851 MHz, where the probe input impedance has reduced to 267 Ω, and a source resistance of
250 Ω the probe output amplitude is reduced to: