Appendix A

Application Note

5.1

DDR3 and DDR4 JEDEC Timing Violations Summary

This Application Note summarizes the JEDEC timing violations for DDR3 and DDR4 
currently supported in Teledyne LeCroy’s Kibra 380 or Kibra 480 Protocol Analyzer. These 
timing parameters are determined based on the CL, CWL, AL and operational timing mode 
specified by the system memory controller and the SPD data in the DIMM. 

5.1.1

V01 - tRAS ACTIVATE to PRECHARGE command period (Min)

The minimum interval between Activate and PreCharge is specified to ensure the active 
row is closed before the next Activate or Refresh. This is the minimum amount of time 
that must occur between activating a row and issuing a precharge to the row in same rank 
and same bank. This makes sure that all the data from the row has been moved to the 
sense amps and is stable before a precharge is issued to write the data back to the row.

5.1.2

V02 - tRAS ACTIVATE to PRECHARGE command period (Max)

The maximum interval between ACTIVATE and PRECHARGE to the same rank and same 
bank is specified and is consistent with the Row to Row Delay (RRD). 9*tREFI is also the 
maximum amount of time between refresh commands. As all Banks must be idle before 
refresh, the maximum amount of time a Row can be active is the maximum amount of 
time between refresh commands. This table is for Tcase = [0‐85°C].

Speed Grade

800

1066

1333

1600

tRASmin (ns)

37.5

37.5

36

35

tRASmin (nCK)

15

20

24

28

Speed Grade

800

1066

1333

1600

tRASmax (ns)

70200

70200

70200

70200

tRASmax (nCK)

28080

37416

46823

56160