Sequence trigger – Teledyne LeCroy Kibra DDR User Manual

Page 65

Advertising
background image

    

Kibra DDR Protocol Analyzer User Manual

63

Recording Options Setup

  Teledyne LeCroy

Sequence Trigger

Sequence triggers can be set to be performed on signals. The options are:

Arm on

Signals ‐ Click the link to open the DDR Select Signals dialog (see 

Figure 2.34 

on page 65

.)

No Arm

Trigger on

Signals ‐ Click the link to open the DDR Select Signals dialog (see 

Figure 2.34 

on page 65

.)

Trigger After ‐ specified (nck)

Reset Arm

Never

Signals ‐ Click the link to open the DDR Select Signals dialog (see 

Figure 2.34 

on page 65

.)

After ‐ specified (nck)

Figure 2.32: Sequence Trigger Settings

Note:

Hold mouse over fields to display tooltips.

The Sequence Trigger feature provides a powerful triggering engine which allows for 
defining the trigger at the signal level with arm and roll‐back condition. You can define 
the following trigger conditions:

Trigger on any signal transition

Trigger on combination of signals that make a specific command

Trigger on sequence of conditions

Some custom violation detection sequences

The advance trigger has three major conditions:

Arm condition: This condition is used to define condition before trigger.

Reset‐Arm condition: This condition causes resetting of the Arm condition. 