Kibra DDR Protocol Analyzer User Manual

53

Recording Options Setup

  Teledyne LeCroy

options from the drop‐down menu to display their values. Refer to 

Figure 2.20

 through 

Figure 2.23

.

The Timing Violation Trigger check‐box (refer to 

Figure 2.20) 

will configure the analyzer to 

trigger when any selected Timing Violation occurs. When the Violation triggers are 
selected, they will be "OR" conditioned with any other trigger events that are also active. 
Users may customize the individual trigger events by enabling or disabling the check box 
next to the Violation number. 

Note:

The timing and protocol violations specified in this window will also be used to identify possible 

errors in the trace during post process analysis. The post process error analysis occurs whether 
the check box for the specific violation is enabled or disabled.

Figure 2.20: Timing Violation Trigger Values for DRAM Operations - DDR3