109

IBTracer 4X Protocol Analyzer User’s Manual

CATC

SW Version 2.2

Running Disparity Error - If a trace has errors, Running Disparity Errors
will display as a column in the window. Running Disparity is maintained
within each of the four lanes.

Raw 10b Codes on traces made by IBTracer (1x)

In traces created by IBTracer (1x), the 10b Codes window displays the data
for a packet within the window, and bytes from each packet as rows.

Byte Name - Displays 10bit code byte name

Byte Value - In hex or decimal. You can toggle the format of this

column by double-clicking the column heading.

Code - Displays the value in either bits or hex for the selected

byte. You can toggle the format of this column from bits to hex
or vice versa by double-clicking the column heading.

Error - If present, errors will display as red X’s. Use the buttons

marked Running Disparity Error to scroll through the errors.

Current RD - Shows current Running Disparity as + or -.

Fields - Shows the fields for each byte.