55

IBTracer 4X Protocol Analyzer User’s Manual

CATC

SW Version 2.2

Actions Window Layout

The Actions window displays three groups of buttons that can be connected
by dragging the mouse: Event buttons, Action buttons, and Counters.

Event Buttons

Event buttons represent the events you selected in the Events window.
These buttons are created automatically when you make your choices in the
Events window. If no events are selected, no Event buttons will appear.

By default, Event buttons are connected to the Trigger button.

Action Buttons

Buttons marked Trigger, Filter In, Filter Out, and Restart are Action
buttons. These buttons determine the outcome of an event.

Trigger Button - Triggers the end of the recording when an event occurs.

Filter In and Filter Out Buttons - Tells the Analyzer to filter in or out

events from the recording. Filtering lets you exclude unwanted
traffic so that you can preserve recording memory and thereby
increase amount of desired traffic in your trace.

Restart - This button is used to restart Counts and Event Sequences. See

below for an explanation of Counts and Event Sequences.

Counters

Action
Buttons

Event
Buttons