Teledyne LeCroy PETracer PCI Express Edge User Manual User Manual
Page 131
PETracer Edge User Manual
Chapter 8: Recording Options
Teledyne LeCroy
123
Note: The Mask (hex) and Match (hex) entries represent bitmask in hex format. As you
type entries in the bitmask, corresponding values appear in fields in the hex Mask and
Match. Alternately, you can type values in the hex Mask and Match, and corresponding
values appear in the bitmask.
Example 1
To tell the Analyzer to trigger on any payload with the binary pattern 1111111 in the third
DWORD:
Step 1 Create an Any TLP event in the Available Events area of Recording
Rules. Drag the event to the Global State cell.
Step 2 Open the Properties dialog box for the event and bring up the Payload pane.
Step 3 Enter 3 in the Offset dword area of any of the four patterns (0 to 3). For
purposes of this example, we choose pattern 2.
Step 4 Enter the following in pattern 2: 1111111.