Multi - link triggering, Set timers – Teledyne LeCroy STX M6-1 SAS_SATA Protocol Analyzer User Manual User Manual

Page 108

Advertising
background image

LeCroy Corporation

Easy Mode (Pre‐Defined Setups)

106

 

 

Sierra M6‐4 SAS/SATA Protocol Analyzer User Manual

6. Choose pattern(s) and click the +>> button to add them for capture or exclusion. You

define each pattern the same way as in Easy mode (

“Defining Patterns” on page 60

).

7. For an output trigger, click the down arrow in the Ext. Out field and choose an

output trigger level. Note: Do not use the LOW setting in Advanced Mode.

8. To go to another state, click the down arrow in the Go To field and select a state. If

no other state has been defined, choose New State to add a state.

Multi - Link Triggering

You can set different triggering for each link. To set different trigger conditions for a link,
check the Multi Sequencer check box and select the link for setup from the Port drop‐
down list.

Figure 2.80: SAS: Multi - Link Triggering Setup

Set Timers

You can set and use up to three timers for triggering. You can set each timer for each
state, or set it to continue from one set in the previous state. The timer defined for a
particular state starts when the system enters that state. You can set a timer for any IF or
ELSE IF condition. To set up the timers, click the ellipses in the Timer field next to the IF
or ELSE IF condition in each state and define each of the timers in the Set Timers dialog.

Figure 2.81: Set Timers Dialog

Advertising