Vanguard CT-6500 S2 User Manual

Page 46

Advertising
background image

CT-6500 Series 2 Operating Instructions

45

9.7 Deleting a Timing Test Record

Users can delete a specific timing test record or all of the timing test records from the CT-

6500’s EEPROM by using the steps in Table 12.0.

Table 12.0 Deleting a Timing Record

STEP OPERATION

ACTION

DISPLAY

1

SELECT SET UP MENU.

PRESS # 3 KEY.

1.ANALYSIS POINTS

2.MEASUREMENT UNITS

3.SAVE / RESTORE

4.NEXT PAGE

2

SELECT SAVE / RESTORE MENU.

PRESS # 3 KEY.

1.SAVE SHOT

2.RESTORE SHOT

3.SHOT DIRECTORY

4.ERASE SHOT

3

SELECT ERASE SHOT.

PRESS # 4 KEY.

1.ERASE SHOT

2.ERASE ALL SHOTS!

4

SELECT ERASE SHOT.

PRESS # 1 KEY.

ENTER SHOT NUMBER

TO BE ERASED

XXXX

"ENTER" TO CONFIRM

5

ENTER SHOT NUMBER “1” TO BE

ERASED.

PRESS KEYS 0-9 TO

SELECT SHOT

NUMBER, PRESS

THE "ENTER" KEY

TO CONFIRM.

ERASE SHOT # 0001

TEST: OPEN

DATE: 03\12\07 09:12

"ENTER" TO CONFIRM

6

CONFIRM TO ERASE SHOT.

PRESS THE

"ENTER" KEY.

ERASE IN PROCESS

PLEASE WAIT

7

WAIT FOR SHOT BEING ERASED.

NO ACTION.

ERASE COMPLETE

8

RETURN TO MAIN MENU.

PRESS ANY KEY.

1.RUN TEST 06/10/07

2.GET RESULTS 20:10:01

3.SETUP

4.DIAGNOSTIC

Advertising