9.20 Print Test Record Data

Print data command allows the user to print the hexadecimal timing data collected by the CT-
6500. This feature is mainly for factory testing. The CT-6500 collects 20,000 data points in the
one-second timing window. As a results, each data sample is 0.05 ms apart. By looking at the
time marker and the data point, the user can actually find the channel activities vs time in the
timing record.
The following steps allow the user to print CT-6500 timing data from memory.


Table 25.0 Print Test Record Data

STEP OPERATION

ACTION

DISPLAY

1

SELECT DIAGNOSTIC.

PRESS # 4 KEY.

1. SLOW-CLOSE TEST

2. CHECK HOOKUP

3. TEST TRANSDUCER

4. NEXT PAGE

2

SELECT NEXT PAGE.

PRESS # 4 KEY.

1. PRINT DATA

2. ENCODER FILTER

3. CONTACT FILTER

3

SELCT PRINT DATA.

PRESS # 1 KEY.

STARTING ADDRESS?:

4

ENTER ADDRESS BOUNDARY

(See note below)

PRESS KEY # 1 to 9

1. EVERY POINT

2. EVERY 5 POINTS

5

CT-6500 PRINTS DATA.

NONE.

1. EVERY POINT

2. EVERY 5 POINTS

6

RETURN TO MAIN MENU.

PRESS THE "STOP"

KEY.

1.RUN TEST 06/10/07

2.GET RESULTS 20:10:01

3.SETUP

4.DIAGNOSTIC

As sample of the CT-6500 timing data print out is shown in Figure 21.0.

Note

Pressing key #0 will start printing the data at address location 0 (or the first data point)
Pressing key #1 will start printing the data at address location .10000 second.




Figure 21.0 CT-6500 Timing Data