E Series - 12 Lead ECG Monitoring Option Insert

8

9650-1218-01 Rev. B

.

Sending Reports Via Bluetooth or Direct
FAX

The E Series unit can send 12 lead data in three different
modes:

In ZOLL Data Relay mode, reports are sent to a
single predefined recipient automatically with no
action required on the part of the user. Prior to
enabling Data Relay mode, the transmission method
(ZDR Mobile, ZDR Server, or ZDR RS-232) must be
set. For the ZDR Server method, the recipient must
be set.

In automatic transmission mode, the Transmission
setup menu appears after acquisition to allow the
user to select a destination from a pre-defined list, or
enter a phone number manually.

In the 12-lead menu on the unit, stored patient
records can be sent at any time.

There are three transmission methods for sending 12
lead data:

To a PDA or PC using either the ZDR Mobile or
ZDR RS-232 connection. ZDR Mobile uses the
Bluetooth wireless connection in the E Series unit to
communicate with a PDA or PC running ZOLL Data
Relay software. ZDR RS-232 uses a serial cable to
connect to the PDA or PC. The PDA or PC then
forwards the received information to a ZOLL Data
Relay server for delivery to the designated recipient.

To a ZDR server. This transmission method uses the
Bluetooth wireless connection in the E Series unit to
connect to a cellular phone using Dial Up
Networking. The cellular phone then connects
through the Internet to a ZOLL Data Relay server,
which then sends the report to the designated
recipient. The ZDR server transmission can be used
in any of the sending modes described above.

To a Direct FAX. Direct FAX sends a FAX via the
PCMCIA modem card in the E Series unit,
connecting to either a land line or a FAX capable
cellular phone. Direct FAX can be used in automatic
transmission mode, or for sending patient records.

Sending reports:

Data Relay mode: Prior to sending reports, the Data
Relay Configuration must be set. This is only
available on units with the Bluetooth option. Press
the Param softkey, highlight ZDR Dest. using the
Select softkey, then press the Enter softkey. Choose

CAUTION

Transmission of 12-lead ECG data via cellular phones
can be less reliable than transmission via landline
connections. A strong signal and stationary
transmission improves the transmission’s success rate.
Follow the directions provided with your cellular phone.

either ZDR RS-232 or ZDR Mobile to send to a PDA or
PC. Selecting the ZDR Server entry brings up a screen
of available contacts. Use the scroll keys on top of the
unit to highlight the desired recipient, then press the
Return softkey.

To start Data Relay automatic transmission of 12 lead
reports (and trend data if enabled), press the Summary
button and then the Data Relay On softkey. To stop
Data Relay transmission, press the Summary button,
then the Data Relay Off softkey.

Automatic Transmission after acquisition: this
mode must be enabled by setting the Auto Transmit
After 12 Lead option to Yes in the System Configuration
menu. After successful acquisition of a 12 lead, the
Transmission Setup screen will appear (see below).

Patient Record transmission: To send previously
acquired patient records, press the 12 Lead softkey,
then PT Info and then Patient Records. Use the scroll
keys on top of the unit to select the desired record, then
press the Transmit softkey. After retrieving the record,
the Transmission Setup screen appears.

Transmission Setup:

The screen displays a list of recipients; use the scroll keys
on top of the unit to select the desired recipient.

Press Xmit Now to send the report, or Cancel Xmit to
cancel. The transmission icon will appear in the upper
left-hand corner of the screen during a Bluetooth
transmission. When the transmission is finished, the
message TRANSMISSION COMPLETED appears.

Note: For DUN transmission to succeed, the receiving

Bluetooth phone must be turned on. The phone
display may ask the user to accept the connection
to the E Series unit. If possible, the receiving phone
should be set to automatically accept connections
from the E Series unit.

To send a report via Direct FAX to a phone number not on
the list, press the Manual Dial softkey.

Xmit

Now

Manual

Dial