Encoder adjustment submenu (Encoder)

Rotate the horizontal ([) or vertical adjustment knob ({) to select from four levels (0 to 3)
of encoding to maintain image sharpness. The default is 2.

Zoom Menu (Zoom)

The following flowchart provides an overview of the Zoom menu.

Zoom

Hzm 0512
Vzm 0512

MENU

NEXT

NEXT

Zoom control
• Zoom in and out starting

with the current size
(default is 512)

Filters

Figure 17.

Zoom Menu

Zoom in/out adjustment submenu (Zoom)

Rotate the horizontal ([) or vertical adjustment knob ({) to adjust the zoom settings of a
displayed image. The zoom adjustment increases or decreases the overall size of an image
and is based on the current size setting. See

Front Panel Features

in this section for a

description of the Size button.

NOTE: The default value for horizontal and vertical size is 0512. The default values

for the horizontal and vertical shift are 2048 and 1024, respectively. The actual
minimum and maximum values will vary and are based on the incoming scan
rate.

Genlock Menu (Genlock)

The following flowchart describes the Genlock menu. Genlocking is available on the
VSC 700 and 700D only.

Genlock

Hph Sub

128 128

MENU

NEXT

NEXT

Horizontal phase and
Subcarrier phase

• Adjust either phase from 0 to

255 (default is 128).

Zoom

Figure 18.

VSC 700 and 700D Genlock Menu

Horizontal and Subcarrier Phase submenu (Hph Sub)

Rotate the horizontal ([) and vertical adjustment knob ({) to adjust the horizontal phase
and color subcarrier phase, respectively (see

Genlock and Vertical Interval Switching

in

this section). Adjust either phase from 0 to 255. The default is 128.