Command and Response Table for SIS Commands: VSC 500/700/700D

Command Description

ASCII Command

Response

Additional Description

Horizontal Shift

Specify the horizontal
centering value

X1)

H

Hph

X1)

]

Specify the centering value

Decrement one step

-H

Hph

X1) ]

Shift left one step

Increment one step

+H

Hph

X1)]

Shift right one step

View the horizontal centering
value

H

X1)]

Show the horizontal centering
value

Vertical Shift

Specify the vertical centering
value

X1)

/

Vph

X1)]

Specify the centering value

Decrement one step

-/

Vph

X1)]

Shift down one step

Increment one step

+/

Vph

X1)]

Shift up one step

View the vertical centering
value

/

X1)]

Show the vertical centering value

Horizontal Size

Specify the horizontal size
value

X1)

:

Hsz

X1)]

Specify the horizontal size value

Decrease horizontal size one
step

-:

Hsz

]

Decrement the horizontal size

Increase horizontal size one
step

+:

Hsz

]

Increment the horizontal size

View the horizontal size value

:

X1)]

Show the horizontal size value

Vertical

Size

Specify the vertical size value

X1)

;

Vsz

X1)]

Specify the vertical size value

Decrease vertical size by one
step

-;

Vsz

]

Decrement the vertical size

Increase vertical size by one
step

+;

Vsz

]

Increment the vertical size

View the vertical size value

;

X1)]

Show the vertical size value

Zoom Mode

Zoom in

+{

Zom

]

Zoom in

Zoom out

-{

Zom

]

Zoom out

Freeze Mode

Enable freeze mode

1F

Frz 1

]

Freeze the video output

Disable freeze mode

0F

Frz 0

]

Unfreeze the video output

View freeze mode status

F

X@]

Show freeze mode status (on = 1,
off = 0)

Front Panel Security Lockout (executive mode)

Enable executive mode

1X

Exe 1

]

Lock front panel adjustments;
adjust image via RS-232 only

Disable executive mode

0X

Exe 0

]

Unlock front panel adjustments

View executive mode status

X

X@

]

Show executive mode status (on=1,
off = 0)

Zap - Reset to Default Settings

System reset

E

zXXX

}

ZapXXX

]

Reset all settings to factory defaults