Command and response table for sis, Commands: vsc 700/700d only, Command and response table for special – Extron Electronics VSC 500_700_700D User Guide User Manual

Page 31: Function sis commands: vsc 700/700d only

Advertising
background image

Command Description

ASCII Command

Response

Additional Description

Firmware Version, Part Number and Information Requests

Query firmware version
number

Q/q

x.xx

]

Display firmware version

Request part number for VSC
500

N/n

60-476-01

]

Display part # for VSC 500

Request part number for VSC
700

N/n

60-477-01

]

Display part # for VSC 700

Request part number for VSC
700D

N/n

60-477-02

]

Display part # for VSC 700D

Request information

I/i

Hrt

X!

Vrt

X!]

Display status of VSC

Command and Response Table for SIS Commands: VSC 700/700D Only

Command Description

ASCII Command

Response

Additional Description

Horizontal Filter (detail)

Specify the horizontal filter
value

X1!

D

Dhz

X1!]

Specify the detail value

Decrement one step

-D

Dhz

X1!]

Decrease the detail level by one
step

Increment one step

+D

Dhz

X1!]

Increase the detail level by one step

View the horizontal filter value

D

X1!]

Show the horizontal detail level

Flicker Filter

Specify the flicker filter value

X1!

d

Dvz

X1!]

Specify the flicker value

Decrement one step

-d

Dvz

X1!]

Decrease the flicker by one step

Increment one step

+d

Dvz

X1!]

Increase the flicker by one step

View the flicker filter value

d

X1!]

Show the flicker value

Command and Response Table for Special Function SIS Commands:

VSC 700/700D Only

The syntax for setting a special function is

X\

*_ # where _ is the function number and

X\

is the value. To view a function’s setting, use _# where _ is the function number. In

the following table the values of the

X\

variable are different for each command/function.

These values are given in the rightmost column.

Command Description

ASCII Command

Response

Additional Description

Encoder Filter (sharpness)

Specify the encoder filter level
Example:

X\

* 10#

3 * 10#

Enc

X\]

Enc 03

]

Specify the encoder filter level (0 - 3)
Example: set the encoder filter level to 3

View the encoder filter level

10#

X\]

Show the encoder filter level

VSC 500/700/700D User Guide • Serial Communication

25

Advertising