5.6 System Fan Replacement

To replace the system fan, please follow the instructions below.

CAUTION:

Carefully note the direction and orientation of the existing system fan prior to

replacement.

Turn off and disconnect the workstation from all power sources.

Remove the workstation from the rack in which it is installed.

Open the top cover of the RPC-6022GW Rackmount LCD Workstation.

(See Section 4.5.1)

Disconnect the system fan from the PSU.

Remove the CPU card clamp (See Section 4.5.2).

Remove the defective cooling fan by removing two screws that secure the fan to

the CPU card clamp (Figure 5-3).

Figure 5-3: System Fan Retention Screws

Install the new system fan. Secure the fan with retention screws.

Connect the new system fan to the PSU.