1 gp-4100 series, Chapter 2 part names and functions – Proface GP4100 - 3.4 Compact HMIs" User Manual

Page 27

Advertising
background image

GP-4100 Series Hardware Manual

2-2

2.1

GP-4100 Series

A: Power Connector

B: Serial Interface (COM1)
RS-232C and RS-422/485 Types: 9-pin, 2-piece
terminal block
RS-485(isolation) Type: D-Sub 9 pin (socket)

C: USB (Type A) Interface (USB1)
Complies with USB 2.0, Uses a “TYPE-A”
connector. Power supply voltage: DC5±5%,
The maximum communication distance: 5 m.

D: USB (mini-B) Interface (USB2)
Conforms to USB2.0 (mini-B) x 1
Communication Distance: 5 m or less

E: DIP Switch (SW1)
A terminating resistor can be inserted using the
DIP Switch (4-bit) on the rear of the RS-422/485
type. Factory default settings are all set to “OFF”
(no terminating resistor).

• If connecting a bar code

reader to the GP, be sure

to supply power from an

external source (such as a

self-powered hub). If you

supply power from the GP,

the GP may reset itself

because the GP cannot

supply enough power.

Check the terminating resistor

required for connection to the

connected device (PLC) and

install if necessary. For detailed

information, refer to the GP-Pro

EX Device/PLC Connection

Manual.

A

RS-485 (isolation) Type (GP-4107)

C

D
B
E

Right side

Rear

(RS-422/485 Type)

Right side

Rear

A

C

D
B

RS-232C and RS-422/485 Types
(GP-4105, and GP-4106)

Ethernet Type (GP-4104)

A

C

D

F

Right side

Rear

ACT LED

LINK LED