background image

Chapter 2 Specifications

2-7

‹

Input Derating

Using LT input voltage that exceeds the rated voltage, the input ON voltage, the number of input points or the

LT’s temperature can effect. Also, the LT’s input section could overheat, which could lead to an accident or

malfunction. Refer to the following drawing and perform Input Derating within the LT unit’s rated range.

Input Delay
Time

*1

OFF to ON

0.5 to 20ms

*2

ON to OFF

0.5 to 20ms

*2

Input Signal Display

No LED indicators

Status Display

None

Isolation Method

Photocoupler Isolation

External Connection

22-pin connector (used with Output section)

External Power Supply

For Signal: DC 24V

*1

In the case of IN0, IN2, IN4, and IN6, the input delay time generates a 5µs-

delay. For example, in the case of a 0.5ms-cycle sampling:

5µs (ON to OFF) + 0.5ms (sampling cycle) + 5µs (OFF to ON) = 0.51ms

A minimum 0.51ms-restriction is imposed on the input pulse width.

In the case of IN1, IN3, IN5, and from IN7 to IN11, the input delay time gen-

erates a 0.5ms-delay. For example, in the case of a 0.5ms-cycle sampling:

0.5ms (ON to OFF) + 0.5ms (sampling cycle) + 0.5ms (OFF to ON) = 1.5ms

A minimum 1.5ms-restriction is imposed on the input-pulse width.

*2

Digital filter can be set at intervals of 0.5 ms.

(%)

100

50

0

0

10

20

30

40

50 (

°C)

In

put

ON Rat

e

Surrounding Operating Temperature

DC24.0 to DC26.4V

DC28.8V

Advertising