Proface LT3300 - 5.7 All-in-One HMI" User Manual

Page 35

Advertising
background image

LT3000 Series Hardware Manual

2-8

Input Circuit

‹

Output Specifications

Output Terminal

OUT0 to OUT3

OUT4 to OUT5

Rated Voltage

DC24V

Allowable Voltage Range

DC20.4V to DC28.8V

Output
Method

LT3201-A1-D24-K

Sink Output

LT3201-A1-D24-
C

Source Output

Maximum Load Voltage

0.2A/point, 1.2A/common

Output Voltage Drop

DC 0.5V or less

Output
Delay Time

OFF to ON

5µs or less (With output
at DC24V, 200mA)

0.5ms or less (With
output at DC24V,
200mA)

ON to OFF

5µs or less (With output
at DC24V, 200mA)

0.5ms or less (With
output at DC24V,
200mA)

Voltage Leakage (when OFF)

0.1mA or less

Clamp Voltage

39V ± 1V

Type of Output

Transistor Output

Common Lines

1

Common Design

6 points/1 common line

External Connection

22-pin connector (also used for Input)

Output Protection Type

Output is unprotected

Internal Fuse

2.5A, 125V Chip fuse (not replaceable)

Surge Control Circuit

Zener diode

Output Points

6

Output Signal Display

No LED indicators

Status Display Element

None

Isolation Method

Photocoupler Isolation

External Power Supply

For Signal: DC 24V

DC 24V

External Power

Internal Circuit

Internal Circuit

COM B7

+ -

IN11

A6

-

+

*1

*1

Dotted line shows connection to sink output type.

IN10 B6
IN9

A5

IN8

B5

IN7

A4

IN6

B4

IN5

A3

IN4

B3

IN3

A2

IN2

B2

IN1

A1

IN0

B1

Advertising