4 prior to operating the ps-a unit, 1 front access mask, 2 power supply – Proface APL3000B - Node Box PC User Manual

Page 20: 4 prior to operating the ps-a unit -7, 1 front access mask -7, 2 power supply -7, Prior to operating the ps-a unit, 7 1.4 prior to operating the ps-a unit

Advertising
background image

Chapter 1 Overview

1-7

1.4

Prior to Operating the PS-A Unit

1.4.1

Front Access Mask

When you open the PS-A’s front maintenance hatch, there are a front USB port and a Hardware Reset Switch.

If you want to restrict access or prevent unintentional access from the Front USB port or Hardware Reset

Switch, change the settings of the DIP Switch on the circuit board in PS-A unit for Front Access Mask.

See the following for DIP Switch details.

1.4.2

Power Supply

The PS-A unit’s power supply has three states; Non-energized, Active State (Normal), and Soft OFF State

*1

.

Each state is outlined in the following.

*2

SEE

2.4 DIP Switches (page2-14)

*1

The Soft OFF refers to the state that Windows

®

has been shut down and the power is provided only for

the electric circuit to boot system. This Soft OFF State is different from what is System Standby set by

Windows

®

.

*2

See "„ RAS Input Start (page2-12)" for details. This feature is only available for RAS port type.

Power State :

Screen of PS-A :

Power LED :

Non-energized

OFF

OFF

Active State (Normal)

ON

Green Lighting

Soft OFF

OFF

Green Blinking

PS-As
power On

PS-A’s system
activated

Shut down by
Windows program

System
Stop

Hardware Reset
Switch ON or
RAS Input Start

*

2

Power Switch OFF,
Remove Power
Cable

for Normal State

for Non-energized
State

Advertising