PS-3650A/PS-3651A Series Hardware Manual

3-4

• Be sure that the ambient operation temperature and the ambient humidity are within

their designated ranges. When installing the PS-A unit on the panel of a cabinet or

enclosure, “Ambient operation temperature” indicates both the panel face and

cabinet or enclosure’s internal temperature.

• Be sure that heat from surrounding equipment does not cause the PS-A unit to

exceed its standard operating temperature.

• When installing the PS-A unit in a slanted panel, the panel face should not incline

more than 30°.

• When installing the PS-A unit in a slanted panel, and the panel face inclines more

than 30°, the ambient temperature must not exceed 40°C. You may need to use

forced air cooling (fan, A/C) to ensure the ambient operating temperature is 40°C or

below.

• The PS-A unit does not support longitudinal mounting.

50 [1.97]

30[1.18]

30[1.18]

Panel
face

Inside of the

enclosure

Unit: mm [in.]

30° or less