Chapter 2 Specifications

2-17

„ Serial Mode Select SW

The factory setting is RS-232C. Only Switch No.1 is set to ON.

Switch

No.

Description

ON

OFF

RS-232C

RS-422

RS-485

(Data is not

automatically
controlled via

the RTS

signal.)

*1

*1 This setting determines whether or not the TXD output driver is automatically controlled via the RTS

signal.

RS-485
(Data is

automatically

controlled via

the RTS

signal.)

*1

1

Changes
COM1’s
communication
method

RS-232C

RS-422/

RS-485

ON

OFF

OFF

OFF

2

Changes
COM1’s
communication
method

RS-422/

RS-485

RS-232C

OFF

ON

ON

ON

3

Changes
COM1’s
communication
method

RS-422/

RS-485

RS-232C

OFF

ON

ON

ON

4

Changes TX
data’s output
mode

TX data output
is controlled
via the RTS
signal.

TX data output
is NOT
controlled via
the RTS signal.
(normally
output)

OFF

ON/
OFF

ON

OFF

5

Switches the
TX termination
resistance ON/
OFF

Inserts
termination
resistance of
220

Ω between

TXA and TXB.

No
termination

OFF

ON

ON/OFF

*2

*2 If you use the termination resistance, base your settings on the connection specifications.

ON/OFF

*2

6

Switches the
RX termination
resistance ON/
OFF

Inserts
termination
resistance of
220

Ω between

RXA and
RXB.

No
termination

OFF

ON

ON/OFF

*2

ON/OFF

*2

7

Switches the
shorting of TXA
and RXA ON or
OFF

Shorts TXA
and RXA (RS-
485 mode)

No shorting
(RS-422
mode)

OFF

OFF

ON

ON

8

Switches the
shorting of TXB
and RXB ON or
OFF

Shorts TXB
and RXB (RS-
485 mode)

No shorting
(RS-422
mode)

OFF

OFF

ON

ON

9

RTS Automatic
control mode

*1

(enabled only
when RS-485
mode)

The data is
automatically
controlled via
the RTS
signal.

The data is not
automatically
controlled via
the RTS signal.

OFF

OFF

OFF

ON

10

OFF

OFF

OFF

ON

Table 2) Serial Mode Select SW