3 periodic check points, 3 periodic check points -5, Periodic check points – Proface APL3000B - Node Box PC User Manual

Page 74: 5 4.3 periodic check points

Advertising
background image

Chapter 4 Maintenance

4-5

4.3

Periodic Check Points

To keep your PS-A unit in its best condition, please inspect the following points periodically.

„ PS-A Operation Environment

Is the operating temperature within the allowable range?

(PS-3650A Series)

(PS-3651A Series)

Is the operating humidity within the specified range?

10 to 90%RH (Not condensing, wet bulb temperature: 39°C or less, or with HDD 29°C or less.)

Is the operating atmosphere free of corrosive gasses?

When using the PS-A unit inside a panel, the ambient environment refers to the interior of the

panel.

„ Electrical specifications check

Is the input voltage appropriate?

AC Power Supply Type: AC85 to 265V, 50/60Hz

DC Power Supply Type: DC19.2 to 28.8V

„ Related Items

Are all power cords and cables connected properly? Have any become loose?

Are all mounting brackets holding the unit securely?

Are there many scratches or traces of dirt on the installation gasket?

When using HDD

When not using HDD

5 to 50°C

0 to 50°C

When using HDD

When not using HDD

5 to 45°C

0 to 50°C