General-purpose input (din 0, 1) „ ras input start – Proface APL3000B - Node Box PC User Manual

Page 33

Advertising
background image

PS-3650A/PS-3651A Series Hardware Manual

2-12

„ General-Purpose Input (DIN 0, 1)

„ RAS Input Start

RAS Input Start

*1

*2

is a function which allows input to DIN1(+) to start the PS-A unit from Hibernate or Soft

OFF state.

After the input start, DIN1(+) can be used as General-Purpose Input.

Input signal electric specifications is the same as General-Purpose Input

Input Voltage

DC12V to 24V

Input Method

Sink / Source Input

Input Current

10mA (DC24V)

Input Resistance

3.6k

Input Points

2 points (common with external reset input)

Operation Range

ON voltage

DC10V or more

OFF voltage

DC3V or less

Isolation Method

Photocoupler Isolation

Dielectric Strength Voltage

500V or more

• General-Purpose Input (DIN) level must be 1.5 seconds or longer to be detected.

It may not detect under 1.5 seconds.

• Be sure the voltage value between terminals is controlled via the input voltage, so

that the PS-A unit is operated within its recommended range. If the input voltage

exceeds this range, a malfunction or PS-A unit damage may occur.

• The Sink/Source input can be used even if the DIN(-), and RESET(-) are positive,

and DIN(+), RESET(+) are negative. Be sure to operate the unit within the

recommended voltage range.

*1

To use RAS Input Start, set System Set SW 2 No.3 to ON. See "2.4 DIP Switches (page 2-14)" for DIP

Switches details.

*2

Available only for RAS port type.

• PS-A unit will be restarted if you shut down Windows

®

during DIN(+) input. To

change PS-A unit to Soft OFF state, set DIN1(+) input OFF before shutting down

Windows

®

.

(Interface Circuit)

+5V

1.8k

1/10W

1.8k

1/10W

R

R

PC357

No polarity - for Sink /
Source input

switch or other
switching device

Cable

DC12V
to 24V

DINCOM pin # 9

DIN0(+) pin

#

4

DIN1(+) pin

#

5

Advertising