<4. Diagnostics>

4-30

IM 01C25R02-01E

Integral

Indicator

HART

configuration

tool display

Device

Status

Extended

Device Status

Value and Status (Data Quality and Limit Status)

Flow

Differential

Pressure

(DP)

Static

Pressure

(SP)

External

Temperature

(ET)

Total Flow

% range

Loop

current

AL.55

SP. ADJ

SP SPAN

trim err

---

Device

Variable Alert

(0x02)

Value:

Measured

value

Status:

Poor

Accuracy

and

Not Limited

Value:

Measured

value

Status:

Good and

Not

Limited

Value:

Measured

value

Status:

Poor

Accuracy

and

Not Limited

Value:

Measured

value

Status:

Good and

Not

Limited

Value:

Measured

value

Status:

Poor

Accuracy

and

Not Limited

In the case PV is SP

or Flow

Value: Measured

value

Status: Poor

Accuracy and Not

Limited

In the case except

shown above

Value: Measured

value

Status: Good and

Not Limited

SP ZERO

trim err

AL.56

ET. RNG

Illegal ET

LRV

Value: Measured value

Status: Good and Not Limited

In the case PV is ET

Value: Hold value

Status: Bad and

Constant

In the case except

shown above

Value: Measured

value

Status: Good and

Not Limited

Illegal ET

URV

Illegal ET

SPAN

AL.57

ET. ADJ

ET SPAN

trim err

Value:

Measured

value

Status:

Poor

Accuracy

and Not

Limited

Value: Measured value

Status: Good and Not

Limited

Value:

Measured

value

Status:

Poor

Accuracy

and Not

Limited

Value:

Measured

value

Status:

Poor

Accuracy

and Not

Limited

In the case PV is ET

or Flow

Value: Measured

value

Status: Poor

Accuracy and Not

Limited

In the case except

shown above

Value: Measured

value

Status: Good and

Not Limited

ET ZERO

trim err

AL.58

FL. ADJ

F set

outside

Range

Value: Measured value

Status: Good and Not Limited

In the case PV is Flow

Value: Hold value

Status: Bad and

Constant

In the case except

shown above

Value: Measured

value

Status: Good and

Not Limited

AL.59

PLS.ADJ

PLS set err

Value: Measured value

Status: Good and Not Limited

---

ET Fixed

Mode

---

---

Value: Measured value

Status: Good and Not Limited

Value:

Hold value

Status:

Good and

Constant

Value:

Measured

value

Status:

Good and

Not

Limited

In the case PV is ET

Value: Hold value

Status: Good and

Constant

In the case except

shown above

Value: Measured

value

Status: Good and

Not Limited

AL.79

OV.DISP

(None)

---

---

Value: Measured value

Status: Good and Not Limited

*1: Depend on the setting of hardware switch

*2: Depend on the direction of range over (high or low)