pim/dvm intf. group 64 0 64 0 14848 0 24 64

pim/dvm global group 512 0 512 0 14848 6700 46 64

repl entry(Global) 1024 2 1022 0 237568 40644 49 1024

MLD Resources(All Vrfs):

groups 1024 0 1024 0 4096 7100 328 256

phy-ports 2048 0 2048 0 4096 7600 148 256

exist-phy-port 1792 0 1792 0 12992 196484 62 56

group-query 56 0 56 0 12992 0 84 56

Hardware-related Resources:

Total (S,G) entries 2

Total SW FWD entries 0

Total sw w/Tag MVID entries 0

Total sw w/Tag invalid MVID entries 0

Total HW FWD entries 2

Total hw w/Tag MVID entries 2

Total hw w/Tag invalid MVID entries 0

Brocade#

Syntax: show ipv6 pim [ all-vrf | [ vrf vrf-name ] ] resource

The vrf parameter allows you to display hardware resource information for the VRF instance identified
by the vrf-name variable.

The following table displays the output from the show ipv6 pim resource command.

Output from the show ipv6 pim resource command

TABLE 37

Field

Description

Num alloc

Number of allocated PIM resources.

System max Maximum number of VRF resources.

Size

Internal size.

alloc

Number of nodes of that data that are currently allocated in memory.

in-use

Number of allocated nodes in use.

avail

Number of allocated nodes are not in use.

get-fail

Number of allocated notes that failed.

limit

Maximum number of nodes that can be allocated for a data structure. This may or may not be
configurable, depending on the data structure

get-mem

Current memory allocation.

size

Unit size.

init

Initial number.

To display usage and fail-count information for SG entries on each VRF, use the show ipv6 pim all-vrf
hw-resource
command.

device# show ipv6 pim all-vrf hw-resource

VRF In-Use Fail

default-vrf 3072 8

blue 3072 0

-------------------------------

Total usage 6144

IPv6 Multicast Protocols

FastIron Ethernet Switch IP Multicast Configuration Guide

189

53-1003085-02

Advertising