Lun modification considerations, Impact of tape lun configuration changes – Brocade Fabric OS Encryption Administrator’s Guide Supporting RSA Data Protection Manager (DPM) Environments (Supporting Fabric OS v7.2.0) User Manual

Page 194

Advertising
background image

174

Fabric OS Encryption Administrator’s Guide (DPM)

53-1002922-01

Impact of tape LUN configuration changes

3

LUN modification considerations

Make sure you understand the ramifications of modifying LUN policy parameters (such as
encrypt/cleartext) for LUNs that are online and already being utilized. The following restrictions
apply when modifying LUN policy parameters for disk LUNs:

When you change LUN policy from encrypt to cleartext, you wipe out all encrypted data stored
on the LUN the next time data is written to that LUN. The following policy parameters are
disabled:

-

enable_encexistingdata,

-

enable_rekey.

When you change the LUN policy back to encrypt, for example, by force-enabling the LUN,

-

enable_encexistingdata and

-

enable_rekey are disabled by default, and you must configure

both options again.

When you add a LUN as cleartext and later you want to change the LUN policy from cleartext to
encrypt, you must set the

-

enable_encexistingdata option. If you do not, all data on that LUN

is lost, and cannot be recovered.

For tape LUNs, the

-

enable_encexistingdata,

-

enable_rekey, and

-

key_lifespan options are not

valid and therefore cannot be modified. When you attempt to execute these parameters while
modifying a tape LUN, the system returns an error. Disabling

-

write_early ack or

-

read_ahead for

tape LUN will result in lower total throughput depending on the number of flows per encryption
engine.

NOTE

Make sure all the outstanding backup and recovery operations on the media are completed before
changing the LUN configuration.

For disk LUNs

-

write_early_ack and

-

read_ahead are not valid and therefore cannot be modified.

When you attempt to execute these parameters while modifying a disk LUN, the system returns an
error.

Impact of tape LUN configuration changes

LUN-level policies apply when no policies are configured at the tape pool level. The following
restrictions apply when modifying tape LUN configuration parameters:

If you change a tape LUN policy from encrypt to cleartext or from cleartext to encrypt while data
is written to or read from a tape backup device, the policy change is not enforced until the
current process completes and the tape is unmounted, rewound, or overwritten. This
mechanism prevents the mixing of cleartext data to cipher-text data on the tape.

Make sure you understand the ramifications of changing the tape LUN encryption policy from
encrypt to cleartext or from cleartext to encrypt.

You cannot modify the key lifespan value. If you wish to modify the key lifespan, delete and
recreate the LUN with a different key lifespan value. Key lifespan values only apply to
native-mode pools.

Advertising