Decommissioning primary r1 luns only, Decommissioning mirror r2 luns only – Brocade Fabric OS Encryption Administrator’s Guide Supporting RSA Data Protection Manager (DPM) Environments (Supporting Fabric OS v7.2.0) User Manual

Page 197

Advertising
background image

Fabric OS Encryption Administrator’s Guide (DPM)

177

53-1002922-01

Decommissioning replicated LUNs

3

“Decommissioning primary R1 LUNs only”

“Decommissioning mirror R2 LUNs only”

“Decommissioning primary R1 and mirror R2 LUN pairs”

Decommissioning primary R1 LUNs only

To decommission the primary LUN and make the secondary LUN the primary LUN, complete the
following steps. Failure to do so could result in the LUN state showing as Disabled.

1. Log in as Admin or FabricAdmin.

2. Split the R1/R2 sync.

3. Make the R2 LUN write-enabled.

4. Execute the rekey command on the R2 LUN.

FabricAdmin:switch> cryptocfg --manual_rekey <crypto target container name>

<LUN Num> <Initiator PWWN>

5. Decommission the primary LUN.

FabricAdmin:switch> cryptocfg --decommission -container <container name>

-initiator <initiator PWWN> -LUN <lun number>

6. Display the decommissioned key IDs.

FabricAdmin:switch> cryptocfg --show –decommissionedkeyids

7. Delete the respective key from the key vault. On the Brocade Encryption Switch, enter the

following command.

FabricAdmin:switch> cryptocfg --delete –decommissionedkeyids

NOTE

Failure to rekey the secondary LUN might result in loss of data on the secondary LUN after the
primary LUN is decommissioned.

Decommissioning mirror R2 LUNs only

To decommission the secondary LUN, complete the following steps:

1. Log in as Admin or FabricAdmin.

2. Split the R1/R2 sync.

3. Make the R2 LUN write-enabled.

4. Decommission the R2 LUN.

FabricAdmin:switch> cryptocfg --decommission -container <container name>

-initiator <initiator PWWN> -LUN <lun number>

NOTE

Do not delete the key from the key vault.

Advertising