State and status information, In this appendix, Encryption engine security processor (sp) states – Brocade Fabric OS Encryption Administrator’s Guide Supporting RSA Data Protection Manager (DPM) Environments (Supporting Fabric OS v7.2.0) User Manual

Page 317: Appendix a, Appendix a, “state and status information, Appendix

Advertising
background image

Fabric OS Encryption Administrator’s Guide (DPM)

297

53-1002922-01

Appendix

A

State and Status Information

In this appendix

Encryption engine security processor (SP) states . . . . . . . . . . . . . . . . . . . . 297

Security processor KEK status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 298

Encrypted LUN states . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 298

Encryption engine security processor (SP) states

Table 19

lists the encryption engine security processor (SP) states.

TABLE 19

Encryption engine security processor (SP) states

Encryption engine security processor (SP) state Description

Not available

SLOT_XXX_SCN has not been received (debug message).

Not Brocade Encryption Switch or DCX

Debug message.

Not Ready

BLADE_RDY_SCN has not been received (debug message).

Fail to connect to blade

Encryption engine is not connected to the blade processor.

Starting

BLADE_RDY_SCN received and initializing.

SPC Connecting to SP

Establishing connection to CP.

SPC Connected to SP

Connection to CP established.

SP Initialized

SP initialization completed.

Waiting for initnode

SP is awaiting initialization. Run initnode.

Disabled SP

is

disabled.

Encryption engine Faulty

Encryption engine is faulty (BP fault or SP fault). Issue reboot.

Waiting for initEE

SP is awaiting initialization. Run initEE.

Waiting for regEE

SP has its own certificates but is awaiting FIPS certificates. Run
regEE.

Waiting for enableEE

Awaiting the explicit enabling of encryption engine. Run enableEE.

Operational; Not Online

Encryption engine is operational but offline.

Operational; Need Valid KEK

No current master key or primary or secondary link key. Check the
KEK status for more details.

Operational; Need Encryption Group

Encryption engine is operational, but EG is not configured or EG
information is not available. Check EG status.

Online

Encryption engine is online.

Zeroized

Encryption engine is zeroized

INVALID

Encryption engine is invalid

Advertising