Installation:

1. Wrap two turns of 1/2" Teflon tape around threads of the CGA-580 nipple (PN 57150) pressure fitting.

2. Hold the CGA-580 nipple pressure fitting in a vise by flats located on the nipple.

3. Slide the CGA-580 nut (PN 57154) over threads of the CGA-580 nipple pressure fitting.

4. Thread and tighten the adapter fitting (PN 60803) onto the CGA-580 nipple pressure fitting using a 3/4"

wrench.

5. Remove the assembly from the vise and install a cheat seal pad (PN 54854) on the “AN” thread side of

the adapter fitting (PN 60803).

6. Thread into the input hose and tighten using 3/4" and 9/16" wrenches.

4.2.18

AC Fuse (PN 57472), Removal and Installation

1. Disconnect the power cord and line filter. Remove the fuse holder at the AC input.

2. Inspect the fuse. If blown, replace with a 1/2 amp 250 volt, 20mm x 5mm diameter fuse (PN 57472).

3. Replace the fuse holder at the AC input location.

4.2.19

Panel Mounted AC Power/EMI Line Filter (PN 58870), Removal and Installation

Note


See Figure 4-1 on page 5 for wiring diagram.

Tools required:

Phillips screwdriver

1/4" open-end wrench or nutdriver

A/R soldering iron

A/R shrink sleeving (PN 60735)

A/R heat gun

WARNING


Disconnect the power cord from the power source and line filter.

1. Remove the front panel from its enclosure as described in Section 4.2.1 on page 6 and carefully set on a

bench top.

2. Remove the three cable connectors from the line filter terminals.

Note


Some units may not have connectors and will require wire leads to be unsoldered.

3. Loosen and remove the line filter retaining nuts on the rear of panel.

Note


Some units may have screws on the front panel.

4. Remove the AC line filter.
5. To install a new line filter, reverse the order of steps 1 through 4. Connect (or solder) wires to the new

line filter as follows:

Green wire to terminal (E) Ground

White wire to terminal (N) Neutral

Black wire to terminal (P) Line

4.2.20

Power Switch (PN 60307), Removal and Installation

Note


See Figure 4-1 on page 5 for wiring diagram.

Tools required:

Phillips screwdriver

Flat screwdriver

1/4" open-end wrench or nutdriver

A/R soldering iron

A/R shrink sleeving (PN 60735)

A/R heat gun

Advertising