Installation, Installation instructions, Warning caution – Lincoln Electric IM510 RANGER 8 User Manual

Page 10

Advertising
background image

A-3

INSTALLATION

RANGER 8

A-3

INSTALLATION INSTRUCTIONS

Safety Precautions

Machine Grounding

Because this portable engine driven welder or genera-
tor creates it’s own power, it is not necessary to con-
nect it’s frame to an earth ground, unless the machine
is connected to premises wiring (your home, shop,
etc.).

To prevent dangerous electric shock, other equipment
to which this engine driven welder supplies power
must:

be grounded to the frame of the welder using a

grounded type plug, or

be double insulated.

When this welder is mounted on a truck or trailer, it’s
frame must be securely connected to the metal frame
of the vehicle.
Where this engine driven welder is connected to
premises wiring such as that in your home or shop, it’s
frame must be connected to the system earth ground.
See further connection instructions in the section enti-
tled “Standby Power Connections”, as well as the arti-
cle on grounding in the latest U.S. National Electrical
Code and the local code.

In general, if the machine is to be grounded, it should
be connected with a #8 or larger copper wire to a solid
earth ground such as a metal water pipe going into
the ground for at least ten feet and having no insulat-
ed joints, or to the metal framework of a building
which has been effectively grounded. The U.S.
National Electrical Code lists a number of alternate
means of grounding electrical equipment. A machine
grounding stud marked with the symbol is provid-
ed on the front of the welder.

Spark Arrester

Some federal, state, or local laws may require that
gasoline engines be equipped with exhaust spark
arresters when they are operated in certain locations
where unarrested sparks may present a fire hazard.
The standard muffler included with this welder does
not qualify as a spark arrester. When required by
local regulations, the K894-1 spark arrester must be
installed and properly maintained.

An incorrect arrester may lead to damage to the
engine or adversely affect performance.

Trailers

The recommended trailer for use with this equipment
for in plant and yard towing by a vehicle is Lincoln’s
K768-2. Consult applicable federal, state, and local
laws regarding specific requirements for use on public
highways.

If the user adapts a non-Lincoln trailer, he must
assume responsibility that the method of attachment
and usage does not result in a safety hazard nor dam-
age the welding equipment.

Do not attempt to use this equipment until you
have thoroughly read the engine manufacturer’s
manual supplied with your welder. It includes
important safety precautions, detailed engine
starting, operating and maintenance instructions,
and parts lists.

------------------------------------------------------------------------

ELECTRIC SHOCK can kill.
• Do not touch electrically live parts or
electrode with skin or wet clothing.
• Insulate yourself from work and
ground
• Always wear dry insulating gloves.

------------------------------------------------------------------------

ENGINE EXHAUST can kill.
• Use in open, well ventilated areas or
vent exhaust outside.

------------------------------------------------------------------------

MOVING PARTS can injure.
• Do not operate with doors open or
guards off.
• Stop engine before servicing.
• Keep away from moving parts.

------------------------------------------------------------------------

See additional warning information at

front of this operator’s manual.

-----------------------------------------------------------

WARNING

CAUTION