Operation, B-4 welding process – Lincoln Electric IM510 RANGER 8 User Manual

Page 21

Advertising
background image

B-4

OPERATION

B-4

Welding Process

Stick (Constant Current) Welding

Connect welding cables to the "TO WORK” and
"ELECTRODE” studs. Start the engine. Set the
"Polarity” switch to the desired polarity. Set the
“RANGE” switch to a setting that is equal to or slightly
greater than the desired welding current. (The
“RANGE” dial marking indicates the maximum current
for that range). Fine adjustment of the welding current
is made by adjusting the output “CONTROL” or
remote control. For best arc stability, use settings
5 through 10.

The Ranger 8 can be used with a broad range of AC
and DC stick electrodes. See “Welding Tips 1”
included with the Ranger 8 for electrodes within the
rating of this unit and recommended welding currents
of each.

TIG (Constant Current) Welding

The K930-[ ] TIG Module installed on a Ranger 8 pro-
vides high frequency and shielding gas control for AC
and DC GTAW (TIG) welding processes. The TIG
Module allows full range output control. Afterflow time
is adjustable from 0 to 55 seconds.

When using the Ranger 8 for AC TIG welding of
aluminum, the following settings and electrodes are
recommended:

The K930-[ ] TIG Module should be used with the
Ranger 8 on high idle to maintain satisfactory opera-
tion. It can be used in the AUTO position but the
delay going to flow idle after welding is ceased will be
increased if the AFTERFLOW CONTROL is set above
10 seconds.

Wire Feed Welding Processes
(Constant Voltage)

The only Innershield

®

electrode recommended for use

with the Ranger 8 is NR

®

-211-MP. The electrode

sizes and welding ranges that can be used with the
Ranger 8 are shown in the following table:

The Ranger 8 is recommended for limited “MIG” weld-
ing (GMAW - gas metal arc welding). The recom-
mended electrodes are .030” and .035” L-50 and L-56.
They must be used with a blended shielding gas such
as C25 (75% Argon - 25% CO

2

). The welding ranges

that can be used with the Ranger 8 are shown in the
following table:

RANGER 8

SETTINGS FOR PURE TUNGSTEN

TUNGSTEN RANGE SWITCH

APPROXIMATE

DIAMETER (in.) SETTINGS CURRENT RANGE

1/8 70, 90, or 125 80 - 150 Amps

3/32 50, 70, or 90 45 - 130 Amps
1/16 50, or 70 40 - 80 Amps

SETTINGS FOR 1% THORIATED TUNGSTEN

TUNGSTEN RANGE SWITCH

APPROXIMATE

DIAMETER (in.) SETTINGS CURRENT RANGE

1/8 70, 90, 125, or 175 80 - 225 Amps

3/32 50, 70, 90, or 125 50 - 180 Amps
1/16 50, 70, or 90 45 - 120 Amps

Diameter Wire Speed Approximate

(in.) Range In./Min. Current Range

.035

80 - 110

75A to 120A

.045

70 - 130

120A to 170A

.068

40 - 90

125A to 210A

Diameter Wire Speed Approximate

(in.) Range In./Min. Current Range

.030

80 - 110

75A to 120A

.035

70 - 130

120A to 170A